E-Cath® II & E-Cath® II Plus

Echogenic Catheter-Over-Needle System

Product is Available in
ISO Luer and ISO NRFit®

E-Cath® II & E-Cath® II Plus

Echogenic Catheter-Over-Needle System

Developed together with Dr. Ban Tsui, the E-Cath II / E-Cath II Plus combines the best from clinical experience and engineering expertise, resulting in a system that addresses the biggest catheter problems in CNBs: complexity, catheter kinking, anaesthetic leakage and catheter dislocation and migration.4,5,6,7

The results are easier, faster, safer and more reliable continuous nerve blocks with a reduction of workload during postoperative pain management.

CATHETER-OVER-NEEDLE (CON)
TECHNIQUE
Significantly reduces the chance of anaesthetic leakage
and catheter dislocation or migration4
Before Needle Removal
Outer diameter of needle
is smaller than the outer
diameter of the indwelling
catheter.
After Needle Removal
The puncture hole is
automatically sealed
reducing chance for
leakage and dislocation.
CATHETER-OVER-
NEEDLE (CON)
TECHNIQUE
Significantly reduces the chance
of anaesthetic leakage
and catheter dislocation or migration4
Before Needle Removal
Outer diameter of needle
is smaller than the outer
diameter of the indwelling
catheter.
After Needle Removal
The puncture hole is
automatically sealed
reducing chance for
leakage and dislocation.

E-Cath II /E-Cath II Plus Overview

E-Cath II /E-Cath II Plus Features & Advantages

Catheter-Over-Needle Technique

  • Significantly reduces the chance of anaesthetic leakage and catheter dislocation or migration7

Double Layer Catheter Technology

  • Significantly reduces the chance of kinking
  • Allows for consistent anaesthetic flow

Self Priming System

  • E-Catheter comes with a proximal opening which allows the anaesthetic to flow, besides the open tip, also between the outer wall and the indwelling catheter
  • Creates 360 degree flow
  • Improves the U/S-visibility

Soft Tip

  • Reduced chance of nerve damage

Bayonet Lock

  • Ensures a safe and leakage-free connection between the needle / E-catheter and the indwelling catheter
  • Provides audible and haptic click feedback

Non-Removable Injection Tubing

  • Reduction of procedural steps
  • Closed system
  • No leakage
  • Catheter adapter is pre-assembled to the catheter system

Extended E-Catheter Tip (E-Cath Plus only)

  • Protrudes 15 mm past the indwelling catheter
  • Easy placement past the nerve
  • Compensates for minor tissue movement reducing chance of catheter migration

SonoPlex® Features & Advantages

Echogenic Needle Tip

  • Facet tip with two inclination angles
  • Improves needle tip visibility under ultrasound

Cornerstone Reflectors

  • 360 degree graduations on the first 20 mm of the needle
  • Optimised ultrasound visibility of needle shaft and needle tip1
  • Reliable and optimized needle echogenicity at higher angles

NanoLine® Coating

  • Very thin polymer film on inner and outer needle surface
  • Excellent puncture and gliding properties through smooth surface
  • Precise stimulation through the non-insulated needle tip

Self Priming System

  • Needle comes with a distal opening which allows the anaesthetic to flow, besides the needle tip, also between the outer needle wall and the indwelling catheter
  • Improves ultrasound visibility

Depth Markings

  • Easy to read and identify

E-Cath II / E-Cath II Plus Animation Video

E-Cath II /E-Cath II Plus Ordering Info

E-Cath II

Item description Item no. LUER Item no.  Purchase Unit

Indwelling catheter 18G x 50mm (2") / Combined indwelling catheter + E-Cath II (working length) 52mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / Filter 0,2µm / FixoLong

301185-40E 301165-40E 10

Indwelling catheter 18G x 80mm (3 1/4") / Combined indwelling catheter + E-Cath II (working length) 82mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / FixoCath

311285-40E 311265-40E 10

Indwelling catheter 18G x 50mm (2") / Combined indwelling catheter + E-Cath II (working length) 52mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / FixoCath

301285-40E 301265-40E 10

Indwelling catheter 18G x 80mm (3 1/4") / Combined indwelling catheter + E-Cath II (working length) 82mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / Filter 0,2µm / FixoLong

311185-40E 311165-40E 10

Indwelling catheter 18G x 100mm (4") / Combined indwelling catheter + E-Cath II (working length) 102mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / Filter 0,2µm / FixoLong

361185-40E 10

Indwelling catheter 18G x 100mm (4") / Combined indwelling catheter + E-Cath II (working length) 102mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / FixoCath

361285-40E 10

Indwelling catheter 18G x 130mm (5 2/5") / Combined indwelling catheter + E-Cath II (working length) 132mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / Filter 0.2 μm / FixoLong

351185-40E 10

Indwelling catheter 18G x 130mm (5 2/5") / Combined indwelling catheter + E-Cath II (working length) 132mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / FixoCath

351285-40E 10

Indwelling catheter 18G x 150mm (6") / Combined indwelling catheter + E-Cath II (working length) 152mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / FixoCath

371285-40E 10
Item description

Indwelling catheter 18G x 50mm (2") / Combined indwelling catheter + E-Cath II (working length) 52mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / Filter 0,2µm / FixoLong

Item no. LUER 301185-40E 10
Item no. NRFIT 301165-40E 10
Item description

Indwelling catheter 18G x 80mm (3 1/4") / Combined indwelling catheter + E-Cath II (working length) 82mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / FixoCath

Item no. LUER 311285-40E 10
Item no. NRFIT 311265-40E 10
Item description

Indwelling catheter 18G x 50mm (2") / Combined indwelling catheter + E-Cath II (working length) 52mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / FixoCath

Item no. LUER 301285-40E 10
Item no. NRFIT 301265-40E 10
Item description

Indwelling catheter 18G x 80mm (3 1/4") / Combined indwelling catheter + E-Cath II (working length) 82mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / Filter 0,2µm / FixoLong

Item no. LUER 311185-40E 10
Item no. NRFIT 311165-40E 10
Item description

Indwelling catheter 18G x 100mm (4") / Combined indwelling catheter + E-Cath II (working length) 102mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / Filter 0,2µm / FixoLong

Item no. LUER 361185-40E 10
Item description

Indwelling catheter 18G x 100mm (4") / Combined indwelling catheter + E-Cath II (working length) 102mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / FixoCath

Item no. LUER 361285-40E 10
Item description

Indwelling catheter 18G x 130mm (5 2/5") / Combined indwelling catheter + E-Cath II (working length) 132mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / Filter 0.2 μm / FixoLong

Item no. LUER 351185-40E 10
Item description

Indwelling catheter 18G x 130mm (5 2/5") / Combined indwelling catheter + E-Cath II (working length) 132mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / FixoCath

Item no. LUER 351285-40E 10
Item description

Indwelling catheter 18G x 150mm (6") / Combined indwelling catheter + E-Cath II (working length) 152mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G / FixoCath

Item no. LUER 371285-40E 10

E-Cath II Plus

Item description Item no. LUER Item no.  Purchase Unit

Indwelling catheter 18G x 50mm (2") / Combined indwelling catheter + E-Cath II (working length) 65mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G with stylet and 15mm extended tip / Filter 0,2µm / FixoLong

301185-41E 301165-41E 10

Indwelling catheter 18G x 50mm (2") / Combined indwelling catheter + E-Cath II (working length) 65mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G with stylet and 15mm extended tip / FixoCath

301285-41E 10

Indwelling catheter 18G x 80mm (3 1/4") / Combined indwelling catheter + E-Cath II (working length) 95mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G with stylet and 15mm extended tip / Filter 0.2 μm / FixoLong

311185-41E 311165-41E 10

Indwelling catheter 18G x 80mm (3 1/4") / Combined indwelling catheter + E-Cath II (working length) 95mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G with stylet and 15mm extended tip / FixoCath

311285-41E 10
Item description

Indwelling catheter 18G x 50mm (2") / Combined indwelling catheter + E-Cath II (working length) 65mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G with stylet and 15mm extended tip / Filter 0,2µm / FixoLong

Item no. LUER 301185-41E 10
Item no. NRFIT 301165-41E 10
Item description

Indwelling catheter 18G x 50mm (2") / Combined indwelling catheter + E-Cath II (working length) 65mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G with stylet and 15mm extended tip / FixoCath

Item no. LUER 301285-41E 10
Item description

Indwelling catheter 18G x 80mm (3 1/4") / Combined indwelling catheter + E-Cath II (working length) 95mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G with stylet and 15mm extended tip / Filter 0.2 μm / FixoLong

Item no. LUER 311185-41E 10
Item no. NRFIT 311165-41E 10
Item description

Indwelling catheter 18G x 80mm (3 1/4") / Combined indwelling catheter + E-Cath II (working length) 95mm / Needle with Cornerstone Reflectors 21G with Facet S Tip / Indwelling catheter and E-Catheter 20G with stylet and 15mm extended tip / FixoCath

Item no. LUER 311285-41E 10
Downloads

Regional Anesthesia Catalogue Brochure

E-Cath II E-Cath II Plus Brochure

Studies:

1 Fuzier R. et al. The echogenicity of nerve blockade needles, Anesth. 2015; 70: 462–466
4 Ip V. H. Y. et al. The catheter-over-needle assembly offers greater stability and less leakage compared to the traditionalcounterpart in continuous interscalene nerve blocks: a randomized, patient-blinded study, Can. J. Anesth. 2013; 60: 1272–1273
5 Ip V. H. Y. et al. The safety of an interscalene catheter-over-needle technique, Anesth. 2013; 68: 774–775
6 Herring A. A. et al. Emergency department placement of perineural catheters for femoral fracture pain management, Am. J. Emerg. Med. 2014; 32(3), 287: 1–3
7 Tsui B. C. H. et al. Less leakage and dislodgement with a catheter-over-needle versus a catheter through-needle approach for peripheral nerve block: an ex vivo study, Can. J. Anesth. 2012; 59: 655–661 (E-Cath is called Multi-Set in this study)

NRFit® is a registered trademark of GEDSA and is used with their permission

Not all products are registered and approved for sale in all countries or regions. Indications of use may also vary by country and region. Please contact your country representative for product availability and information. Product images are for reference only.