E-Cath® II &
E-Cath® II Plus

Echogenic Catheter-Over-Needle System
Like & Share
"Welcome, I would like to help you. Customer Service "Thank you very much für your inquiry. We will get in touch with you as soon as possible."
Please pick your state and I will notify your local representative to contact you."

E-Cath® II & E-Cath® II Plus

Echogenic Catheter-Over-Needle System

Developed together with Dr. Ban Tsui, the E-Cath II / E-Cath II Plus combines the best from clinical experience and engineering expertise, resulting in a system that addresses the biggest catheter problems in CNBs: complexity, catheter kinking, anaesthetic leakage and catheter dislocation and migration.4,5,6,7

The results are easier, faster, safer and more reliable continuous nerve blocks with a reduction of workload during postoperative pain management

E-Cath II /E-Cath II Plus Overview

E-Cath II /E-Cath II Plus Features & Advantages

Bayonet Lock
  • Ensures a safe and leakage-free connection between the needle / E-catheter and the indwelling catheter
  • Provides audible and haptic click feedback
Catheter-Over-Needle Technique
  • Significantly reduces the chance of anaesthetic leakage and catheter dislocation or migration7
Double Layer Catheter Technology
  • Significantly reduces the chance of kinking
  • Allows for consistent anaesthetic flow
Self Priming System
  • E-Catheter comes with a proximal opening which allows the anaesthetic to flow, besides the open tip, also between the outer wall and the indwelling catheter
  • Creates 360 degree flow
  • Improves ultrasound visibility
Soft Tip
  • Reduced chance of nerve damage
Non-Removable Injection Tubing
  • Reduction of procedural steps
  • Closed system
  • No leakage
  • Catheter adapter is pre-assembled to the catheter system
Extended E-Catheter Tip (E-Cath Plus only)
  • Protrudes 15 mm past the indwelling catheter
  • Easy placement past the nerve
  • Compensates for minor tissue movement reducing chance of catheter migration

SonoPlex® Features & Advantages

Self Priming System
  • E-Catheter comes with a proximal opening which allows the anaesthetic to flow, besides the open tip, also between the outer wall and the indwelling catheter
  • Creates 360 degree flow
  • Improves ultrasound visibility
Echogenic Needle Tip
  • Facet tip with two inclination angles
  • Improves needle tip visibility under ultrasound
Cornerstone Reflectors
  • 360 degree graduations on the first 20 mm of the needle
  • Optimised ultrasound visibility of needle shaft and needle tip1
  • Reliable and optimised needle echogenicity at higher angle
NanoLine® Coating
  • Very thin polymer film on inner and outer needle surface
  • Excellent puncture and gliding properties through smooth surface
  • Precise stimulation through the non-insulated needle tip
Depth Markings
  • Easy to read and identify

E-Cath II & E-Cath II Plus Ordering Info

E-Cath II
Item description Indwelling catheter18G x 50mm (2") | Combined indwelling catheter + E-Cath II (working length) 52mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | Filter0,2µm | FixoLong
Item no. LUER 301185-40E10
Item no. 301165-40E10
Item description Indwelling catheter18G x 80mm (3 1/4") | Combined indwelling catheter + E-Cath II (working length) 82mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | FixoCath
Item no. LUER 311285-40E10
Item no. 311265-40E10
Item description Indwelling catheter18G x 50mm (2") | Combined indwelling catheter + E-Cath II (working length) 52mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | FixoCath
Item no. LUER 301285-40E10
Item no. 301265-40E10
Item description Indwelling catheter18G x 80mm (3 1/4") | Combined indwelling catheter + E-Cath II (working length) 82mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | Filter0,2µm | FixoLong
Item no. LUER 311185-40E10
Item no. 311165-40E10
Item description Indwelling catheter18G x 100mm (4") | Combined indwelling catheter + E-Cath II (working length) 102mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | Filter0,2µm | FixoLong
Item no. LUER 361185-40E10
Item no. 10
Item description Indwelling catheter18G x 100mm (4") | Combined indwelling catheter + E-Cath II (working length) 102mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | FixoCath
Item no. LUER 361285-40E10
Item no. 10
Item description Indwelling catheter18G x 130mm (5 2/5") | Combined indwelling catheter + E-Cath II (working length) 132mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | Filter0.2mm | FixoLong
Item no. LUER 351185-40E10
Item no. 10
Item description Indwelling catheter18G x 130mm (5 2/5") | Combined indwelling catheter + E-Cath II (working length) 132mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | FixoCath
Item no. LUER 351285-40E10
Item no. 10
Item description Indwelling catheter18G x 150mm (6") | Combined indwelling catheter + E-Cath II (working length) 152mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | FixoCath
Item no. LUER 371285-40E10
Item no. 10
E-Cath II Plus
Item description Indwelling catheter18G x 50mm (2") | Combined indwelling catheter + E-Cath II (working length) 65mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G with stylet and 15mm extended tip | Filter0,2µm | FixoLong
Item no. LUER 301185-41E10
Item no. 301165-41E10
Item description Indwelling catheter18G x 50mm (2") | Combined indwelling catheter + E-Cath II (working length) 65mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G with stylet and 15mm extended tip | FixoCath
Item no. LUER 301285-41E10
Item no. 10
Item description Indwelling catheter18G x 80mm (3 1/4") | Combined indwelling catheter + E-Cath II (working length) 95mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G with stylet and 15mm extended tip | Filter0.2mm | FixoLong
Item no. LUER 311185-41E10
Item no. 311165-41E10
Item description Indwelling catheter18G x 80mm (3 1/4") | Combined indwelling catheter + E-Cath II (working length) 95mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G with stylet and 15mm extended tip | FixoCath
Item no. LUER 311285-41E10
Item no. 10
Downloads
E-Cath II E-Cath II Plus Brochure

Studies:

1 Fuzier R. et al. The echogenicity of nerve blockade needles, Anesth. 2015; 70: 462–466
4 Ip V. H. Y. et al. The catheter-over-needle assembly offers greater stability and less leakage compared to the traditionalcounterpart in continuous interscalene nerve blocks: a randomized, patient-blinded study, Can. J. Anesth. 2013; 60: 1272–1273
5 Ip V. H. Y. et al. The safety of an interscalene catheter-over-needle technique, Anesth. 2013; 68: 774–775
6 Herring A. A. et al. Emergency department placement of perineural catheters for femoral fracture pain management, Am. J. Emerg. Med. 2014; 32(3), 287: 1–3
7 Tsui B. C. H. et al. Less leakage and dislodgement with a catheter-over-needle versus a catheter through-needle approach for peripheral nerve block: an ex vivo study, Can. J. Anesth. 2012; 59: 655–661 (E-Cath is called Multi-Set in this study)

NRFit® is a registered trademark of GEDSA and is used with their permission

Not all products are registered and approved for sale in all countries or regions. Indications of use may also vary by country and region. Please contact your country representative for product availability and information. Product images are for reference only.