Echogenic Catheter-Over-Needle System

E-Cath® II &
E-Cath® II Plus

"Welcome, I would like to help you. Customer Service "Thank you very much for your inquiry. We will get in touch with you as soon as possible."
Please pick your state and I will notify your local representative to contact you."

E-Cath® II & E-Cath® II Plus

Echogenic Catheter-Over-Needle System

Developed together with Dr. Ban Tsui, the E-Cath II / E-Cath II Plus combines the best from clinical experience and engineering expertise, resulting in a system that addresses the biggest catheter problems in CNBs: complexity, catheter kinking, anaesthetic leakage and catheter dislocation and migration.4,5,6,7

The results are easier, faster, safer and more reliable continuous nerve blocks with a reduction of workload during postoperative pain management

E-Cath II /E-Cath II Plus Overview

E-Cath II /E-Cath II Plus Features & Advantages

Bayonet Lock

Ensures a strong connection between the indwelling catheter and E-Cath ll catheter:

  • Engagement can be verified by audible and tactile “click” feedback.
Sealed Puncture Site

The puncture site is sealed by the indwelling catheter as it has a larger outer diameter than the puncture needle:

  • After removal of the puncture needle, the tension in the tissue is maintained.
  • The risk of leakage1-4 and dislodgement2-4* is reduced.

    * Only for E-Cath ll, not for E-Cath ll Plus

Two Catheter Layers

Together with the indwelling catheter, the E-Cath ll catheter forms a stable double lumen:

  • This supports the kink stability of the E-Cath ll catheter.
Self Priming System

As a result of the proximal opening, anesthetic flows between the outer wall of the E-Cath II catheter and the inner wall of the indwelling catheter during injection:

  • Echogenic properties are enhanced.
Soft Tip
  • Reduced chance of nerve damage
Integrated Injection Tube

It is permanently secured on the E-Cath ll catheter, no additional handling required:

  • Injection takes place directly via the injection tube.
  • Reduces the risk of leakage.
Extended E-Catheter Tip (E-Cath Plus only)
  • Protrudes 15 mm past the indwelling catheter
  • Easy placement past the nerve
  • Compensates for minor tissue movement reducing chance of catheter migration

SonoPlex® Features & Advantages

Self Priming System

As a result of the proximal opening, anesthetic flows between the outer wall of the E-Cath II catheter and the inner wall of the indwelling catheter during injection:

  • Echogenic properties are enhanced.
Echogenic Needle Tip
  • Facet tip with two inclination angles
  • Improves needle tip visibility under ultrasound
Cornerstone Reflectors
  • 360 degree graduations on the first 20 mm of the needle
  • Optimised ultrasound visibility of needle shaft and needle tip1
  • Reliable and optimised needle echogenicity at higher angle
NanoLine® Coating
  • Very thin polymer film on inner and outer needle surface
  • Excellent puncture and gliding properties through smooth surface
  • Precise stimulation through the non-insulated needle tip
Depth Markings

In solid black:

  • Helps ensure visualization of insertion depth during needle placement.

E-Cath II & E-Cath II Plus Ordering Info

E-Cath II
Item description Indwelling catheter18G x 50mm (2") | Combined indwelling catheter + E-Cath II (working length) 52mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | Filter0,2µm | FixoLong
LUER
Item no.
301185-40E
NRFit®
Item no.
301165-40E
Purchase Unit 10
Item description Indwelling catheter18G x 80mm (3 1/4") | Combined indwelling catheter + E-Cath II (working length) 82mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | FixoCath
LUER
Item no.
311285-40E
NRFit®
Item no.
311265-40E
Purchase Unit 10
Item description Indwelling catheter18G x 50mm (2") | Combined indwelling catheter + E-Cath II (working length) 52mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | FixoCath
LUER
Item no.
301285-40E
NRFit®
Item no.
301265-40E
Purchase Unit 10
Item description Indwelling catheter18G x 80mm (3 1/4") | Combined indwelling catheter + E-Cath II (working length) 82mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | Filter0,2µm | FixoLong
LUER
Item no.
311185-40E
NRFit®
Item no.
311165-40E
Purchase Unit 10
Item description Indwelling catheter18G x 100mm (4") | Combined indwelling catheter + E-Cath II (working length) 102mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | Filter0,2µm | FixoLong
LUER
Item no.
361185-40E
Purchase Unit 10
Item description Indwelling catheter18G x 100mm (4") | Combined indwelling catheter + E-Cath II (working length) 102mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | FixoCath
LUER
Item no.
361285-40E
Purchase Unit 10
Item description Indwelling catheter18G x 130mm (5 2/5") | Combined indwelling catheter + E-Cath II (working length) 132mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | Filter0.2mm | FixoLong
LUER
Item no.
351185-40E
Purchase Unit 10
Item description Indwelling catheter18G x 130mm (5 2/5") | Combined indwelling catheter + E-Cath II (working length) 132mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | FixoCath
LUER
Item no.
351285-40E
Purchase Unit 10
Item description Indwelling catheter18G x 150mm (6") | Combined indwelling catheter + E-Cath II (working length) 152mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G | FixoCath
LUER
Item no.
371285-40E
Purchase Unit 10
E-Cath II Plus
Item description Indwelling catheter18G x 50mm (2") | Combined indwelling catheter + E-Cath II (working length) 65mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G with stylet and 15mm extended tip | Filter0,2µm | FixoLong
LUER
Item no.
301185-41E
NRFit®
Item no.
301165-41E
Purchase Unit 10
Item description Indwelling catheter18G x 50mm (2") | Combined indwelling catheter + E-Cath II (working length) 65mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G with stylet and 15mm extended tip | FixoCath
LUER
Item no.
301285-41E
Purchase Unit 10
Item description Indwelling catheter18G x 80mm (3 1/4") | Combined indwelling catheter + E-Cath II (working length) 95mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G with stylet and 15mm extended tip | Filter0.2mm | FixoLong
LUER
Item no.
311185-41E
NRFit®
Item no.
311165-41E
Purchase Unit 10
Item description Indwelling catheter18G x 80mm (3 1/4") | Combined indwelling catheter + E-Cath II (working length) 95mm | Needle with Cornerstone Reflectors 21G with Facet S Tip | Indwelling catheter and E-Catheter 20G with stylet and 15mm extended tip | FixoCath
LUER
Item no.
311285-41E
Purchase Unit 10

Downloads

Regional Anaesthesia Catalogue

Studies:

1 Fuzier R. et al. The echogenicity of nerve blockade needles, Anesth. 2015; 70: 462–466
4 Ip V. H. Y. et al. The catheter-over-needle assembly offers greater stability and less leakage compared to the traditionalcounterpart in continuous interscalene nerve blocks: a randomized, patient-blinded study, Can. J. Anesth. 2013; 60: 1272–1273
5 Ip V. H. Y. et al. The safety of an interscalene catheter-over-needle technique, Anesth. 2013; 68: 774–775
6 Herring A. A. et al. Emergency department placement of perineural catheters for femoral fracture pain management, Am. J. Emerg. Med. 2014; 32(3), 287: 1–3
7 Tsui B. C. H. et al. Less leakage and dislodgement with a catheter-over-needle versus a catheter through-needle approach for peripheral nerve block: an ex vivo study, Can. J. Anesth. 2012; 59: 655–661 (E-Cath is called Multi-Set in this study)

NRFit® is a registered trademark of GEDSA and is used with their permission

Not all products are registered and approved for sale in all countries or regions. Indications of use may also vary by country and region. Please contact your country representative for product availability and information. Product images are for reference only.