Puncture Needles for Epidural Anesthesia
Tuohy II


Tuohy II
Puncture Needles for Epidural Anesthesia
Epidural anesthesia has a long tradition. As early as 1901, Sicard and Cathelin injected cocaine caudally into the epidural space. In the 1930s, Dogliotti popularized the technique by describing the "loss of resistance technique" for identifying the epidural space. Around twenty years later, in 1949, Curbelo introduced continuous epidural anesthesia.1
Today, the epidural anesthesia is widely used, including major abdominal surgery2, thoracic surgery3, orthopedic surgery4, cardiac surgery3, cesarean section4 and for pain relief during labor analgesia5.
Especially in labor analgesia, the placement of an epidural catheter is considered the most effective method of pain control6. In Germany, according to a 2015 perinatal survey, it is used in 22.1% of obstetric patients7.
Tuohy II Overview

Tuohy II Features & Advantages

Integrated Wings
The ribbed wings with a large contact surface area are firmly attached to the hub:
- Designed for optimized handling for different gripping techniques.

Precision-Manufactured Plastic Stylet
Flush ends of plastic stylet and needle:
- Designed to prevent tissue coring.

Depth Markings
In an intense black color:
- Helps with visualization of insertion depth during needle placement.

Color-Coded Stylet
With size indication:
- For easy identification of the needle size.
Tuohy II (Epidural) Ordering Info
| Item description |
LUER Item no. |
NRFit® Item no. | Purchase Unit |
|---|---|---|---|
| 19G x 90mm (3 1/2") | 1170-6I091 | 1176-6I091 | 10 |
| 18G x 80mm (3 1/4") | 1170-6K081 | 1176-6K081 | 10 |
| 18G x 90mm (3 1/2") | 1170-6K091 | 1176-6K091 | 10 |
| 18G x 103mm (4") | 1170-6K103 | 1176-6K103 | 10 |
| 17G x 80mm (3 1/4") | 1170-6M081 | 1176-6M081 | 10 |
| 17G x 90mm (3 1/2") | 1170-6M091 | 1176-6M091 | 10 |
| 17G x 103mm (4") | 1170-6M103 | 1176-6M103 | 10 |
| 17G x 120mm (4 3/4") | 1170-6M120 | 1176-6M120 | 10 |
| 16G x 80mm (3 1/4") | 1170-6O081 | 1176-6O081 | 10 |
| 16G x 90mm (3 1/2") | 1170-6O091 | 1176-6O091 | 10 |
| Item description | 19G x 90mm (3 1/2") |
|---|---|
|
LUER Item no. | 1170-6I091 |
|
NRFit® Item no. | 1176-6I091 |
| Purchase Unit | 10 |
| Item description | 18G x 80mm (3 1/4") |
|---|---|
|
LUER Item no. | 1170-6K081 |
|
NRFit® Item no. | 1176-6K081 |
| Purchase Unit | 10 |
| Item description | 18G x 90mm (3 1/2") |
|---|---|
|
LUER Item no. | 1170-6K091 |
|
NRFit® Item no. | 1176-6K091 |
| Purchase Unit | 10 |
| Item description | 18G x 103mm (4") |
|---|---|
|
LUER Item no. | 1170-6K103 |
|
NRFit® Item no. | 1176-6K103 |
| Purchase Unit | 10 |
| Item description | 17G x 80mm (3 1/4") |
|---|---|
|
LUER Item no. | 1170-6M081 |
|
NRFit® Item no. | 1176-6M081 |
| Purchase Unit | 10 |
| Item description | 17G x 90mm (3 1/2") |
|---|---|
|
LUER Item no. | 1170-6M091 |
|
NRFit® Item no. | 1176-6M091 |
| Purchase Unit | 10 |
| Item description | 17G x 103mm (4") |
|---|---|
|
LUER Item no. | 1170-6M103 |
|
NRFit® Item no. | 1176-6M103 |
| Purchase Unit | 10 |
| Item description | 17G x 120mm (4 3/4") |
|---|---|
|
LUER Item no. | 1170-6M120 |
|
NRFit® Item no. | 1176-6M120 |
| Purchase Unit | 10 |
| Item description | 16G x 80mm (3 1/4") |
|---|---|
|
LUER Item no. | 1170-6O081 |
|
NRFit® Item no. | 1176-6O081 |
| Purchase Unit | 10 |
| Item description | 16G x 90mm (3 1/2") |
|---|---|
|
LUER Item no. | 1170-6O091 |
|
NRFit® Item no. | 1176-6O091 |
| Purchase Unit | 10 |
Studies:
1 Finucane B. T., Tsui Ban C.H (2017). Complications of Regional Anesthesia - Principles of Safe Practice in Local and Regional Anesthesia. Third Edition, Springer International Publishing AG.
2 Gavriilidis P. et al. (2019). Local anaesthetic infiltration via wound catheter versus epidural analgesia in open hepatectomy: a systematic review and meta-analysis of randomised controlled trials. The Official Journal of the International Hepato Pancreato Biliary Associatio 21(8): 945–952.
3 Rubio-Haro R. et al (2019). Regional analgesia techniques for pain management in patients admitted to the intensive care unit. EDIZIONI MINERVA MEDICA, 85(10): 1118–1128.
4 Beethe A. R. et al. (2020). Neuraxial and regional anesthesia in surgical patients with osteogenesis imperfecta: a narrative review of literature. Regional Anesthesia & Pain Medicine, 45 (12): 993–999.
5 Bernstein K., Landau R. (2021). Management of maternal COVID-19: considerations for anesthesiologists. Current Opinion in Anesthesiology, 34(3): 246–253.
6Knight G. Mushambi M. (2023). Anesthetic challenges of pregnant obesity women. Best Practice & Research Clinical Obstetrics & Gynaecology, 91.
7Deutsche Gesellschaft für Anästhesiologie und Intensivmedizin e.V. (DGAI) (2020). Die geburtshilfliche Analgesie und Anästhesie. S1-Leitlinie der Deutschen Gesellschaft für Anästhesiologie und Intensivmedizin in Zusammenarbeit mit der Deutschen Gesellschaft für Gynäkologie und Geburtshilfe. AWMF online Portal der wissenschaftlichen Medizin, Version 1. Available at register.awmf.org/de/leitlinien/detail/001-038, accessed on 2024-07-02.
NRFit® is a registered trademark of GEDSA and is used with their permission
Not all products are registered and approved for sale in all countries or regions. Indications of use may also vary by country and region. Please contact your country representative for product availability and information. Product images are for reference only.