PAJUNK GLOBAL WEBSITE

SPROTTE®

Needles for Atraumatic Spinal Anaesthesia

The pioneer of atraumatic spinal anaesthesia

Product is Available in
ISO Luer and ISO NRFit®

"Welcome, I would like to help you.

Please pick your country and I will find out your local customer service representative."

Sprotte

Needles for Atraumatic Spinal Anaesthesia

With the introduction of the first atraumatic Sprotte needle at the end of the 1970s, spinal anaesthesia was rehabilitated as a fully accepted alternative to general anaesthesia.
A unique tip geometry is the secret of its success. Sprotte ́s atraumatic puncture and optimal gliding properties minimise possible injuries and prevent foreign bodies and tissue particles from being carried into the subarachnoid space, while reducing the incidence of post-dural puncture headache (PDPH).
In addition, the Sprotte decreases complications of spinal anaesthesia and increases the safety of every application.

Sprotte Overview

Sprotte Features & Advantages

1. Atraumatic Tip

  • Displaces tissue with minimal injury1
  • Dura fibres close again
  • Excellent tactile feedback
  • Minimise chance for PDPH

2. Lateral Eye

  • Burr-free
  • Rounded atraumatic edges
  • Optimised gliding properties
  • Minimum tissue particle carry-over into the spinal space

3. Optimal Lateral Eye Size and Placement

  • Unobstructed backflow, even if the eye is partially blocked by the arachnoid membrane

4. Custom-fit Stylet

  • Lateral eye closes precisely2
  • Polished, rounded tip prevents abrasion on the inner needle tube

5. Highest Processing Quality

  • High quality stainless steel needle for increased stability
  • Smoothly polished and burr-free surface and inner lumen for optimisation of gliding properties and CSF backflow

6. Needle Hub with Reduced Inner Space

  • Fast detection of cerebrospinal fluid for secure placement
  • Immediate detection of even the smallest quantities of CSF

7. Colour Coded Hub with Size Indication

  • Wide needle range with different diameters and lengths
  • Special designs for pediatrics and obese patients

8. Introducer with Facet Tip

  • Diameter and length perfectly matched to each needle size
  • Useable working lenght of the spinal needle is reduced only minimally by the Introducer
  • When inserted into the Introducer, the needle tip is not damaged by the funnel-shaped inner contour

LUER Connector

  • Product Catalogue
  • Downloads
Item descriptionItem no.Purchase Unit

29G x 90mm (3 1/2") with magnification and Introducer

501151-28A25

27G x 25mm (1") with magnification

101151-27A25

27G x 35mm (1 1/3") with magnification

111151-27A2

27G x 70mm (2 3/4") with magnification and Introducer

121151-27B25

27G x 90mm (3 1/2") with magnification and Introducer

121151-27A25

27G x 103mm (4") with magnification and Introducer

141151-27A25

27G x 123mm (4 3/4") with magnification

231151-27A25

27G x 120mm (4 3/4") with magnification and Introducer

151151-27A10

25G x 35mm (1 1/3")

001151-29E25

25G x 70mm (2 3/4") with Introducer 30mm (1 1/5")

021151-29B25

25G x 90mm (3 1/2") with magnification and Introducer

511151-29A25

25G x 90mm (3 1/2")

501151-29A25

25G x 90mm (3 1/2") with Introducer

021151-29A25

25G x 103mm (4") with Introducer

041151-29A25

25G x 103mm (4") with magnification and Introducer

161151-29A25

25G x 120mm (4 3/4")

031151-29A10

25G x 120mm (4 3/4") with Introducer

051151-29A10

25G x 120mm (4 3/4") with magnification and Introducer

171151-29A10

25G x 123mm (4 4/5")

151151-29A10

25G x 150mm (6") with Introducer

061151-29A10

24G x 25mm (1")

001151-30D25

24G x 35mm (1 1/3")

001151-30E25

24G x 70mm (2 3/4")

001151-30B25

24G x 70mm (2 3/4") with Introducer

021151-30B25

24G x 90mm (3 1/2")

001151-30A25

24G x 90mm (3 1/2") with Introducer

121151-30A25

24G x 103mm (4") with Introducer

021151-30A25

24G x 120mm (4 3/4")

031151-30A10

24G x 120mm (4 3/4") with Introducer

041151-30A10

24G x 150mm (6")

141151-30A10

24G x 150mm (6") with Introducer

131151-30A10

24G x 200mm (8") with Introducer 40mm (1 3/5")

0051151-3010

22G x 50mm (2")

071163-30C25

22G x 70mm (2 3/4")

051151-30C25

22G x 70mm (2 3/4") with Introducer

051151-30B25

22G x 90mm (3 1/2")

001151-30C25

22G x 90mm (3 1/2") with Introducer

021151-30C25

22G x 103mm (4")

521151-30C25

22G x 103mm (4") with Introducer 40mm (1 3/5")

221151-30C25

22G x 120mm (4 3/4") with Introducer

131151-30C10

22G x 150mm (6")

041151-30C10

22G x 150mm (6") with Introducer

141151-30C10

0.8 x 30mm (1 1/5") for Sprotte 24G, 25G

021151-30L25

0.8 x 40mm (1 3/5") for Sprotte 24G, 25G

021151-30M25

1.00 x 30mm (1 1/5") for Sprotte 22G

001151-30L25

1.00 x 40mm (1 3/5") for Sprotte 22G

001151-30M25

1.10 x 30mm (1 1/5") for Sprotte 21G

051151-30L25

1.30 x 30mm (1 1/5") for Sprotte 19G

091151-30L25
Items
Sprotte Brochure
Sprotte Instruction for use

NRFit Connector

  • Product Catalogue
  • Downloads
Item descriptionItem no.Purchase Unit

27G x 90mm (3 1/2") with Introducer

021163-27A25

27G x 90mm (3 1/2") with Introducer 30mm (1 1/5"), Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

021166-27A10

27G x 90mm (3 1/2") with Introducer 40mm (1 3/5")

211163-27A25

27G x 90mm (3 1/2") with Introducer 40mm (1 3/5"), Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

211166-27A10

27G x 103mm (4") with Introducer

041163-27A25

27G x 103mm (4") with Introducer 40mm (1 3/5"), Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

041166-27A10

27G x 120mm (4 3/4")

231163-27A10

27G x 120mm (4 3/4") with Introducer

031163-27A10

27G x 120mm (4 3/4") with Introducer 40mm (1 3/5"), Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

031166-27A10

25G x 35mm (1 1/3") with Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

001163-29E25

25G x 90mm (3 1/2")

501163-29A25

25G x 90mm (3 1/2") with Introducer

021163-29A25

25G x 90mm (3 1/2") with Introducer 30mm (1 1/5"), Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

021166-29A10

25G x 90mm (3 1/2") with Introducer 40mm (1 3/5")

211163-29A25

25G x 90mm (3 1/2") with Introducer 40mm (1 3/5"), Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

211166-29A10

25G x 103mm (4") with Introducer

041163-29A25

25G x 103mm (4") with Introducer 40mm (1 3/5"), Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

041166-29A10

25G x 120mm (4 3/4")

031163-29A10

25G x 120mm (4 3/4") with Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

031166-29A10

25G x 120mm (4 3/4") with Introducer

051163-29A10

25G x 120mm (4 3/4") with Introducer 40mm (1 3/5"), Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

051166-29A10

25G x 150mm (6")

261163-29A10

25G x 150mm (6") with Introducer 40mm (1 3/5"), Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

061166-29A10

24G x 25mm (1")

001163-30D25

24G x 25mm (1") with Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

001166-30D10

24G x 35mm (1 1/3")

001163-30E25

24G x 70mm (2 3/4") with Introducer 30mm (1 1/5")

021163-30B10

24G x 90mm (3 1/2")

001163-30A25

24G x 90mm (3 1/2") with Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

001166-30A10

24G x 90mm (3 1/2") with Introducer

121163-30A25

24G x 90mm (3 1/2") with Introducer 30mm (1 1/5"), Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

121166-30A10

24G x 103mm (4") with Introducer

021163-30A25

24G x 103mm (4") with Introducer 40mm (1 3/5"), Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

521166-30A10

24G x 120mm (4 3/4") with Introducer

041163-30A10

24G x 120mm (4 3/4") with Introducer 30mm (1 3/5"), Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

041166-30A10

24G x 150mm (6") with Introducer

131163-30A10

24G x 150mm (6") with Introducer 40mm (1 3/5"), Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

131166-30A10

22G x 50mm (2")

071163-30C25

22G x 90mm (3 1/2")

001163-30C25

22G x 90mm (3 1/2") with Introducer

021163-30C25

22G x 90mm (3 1/2") with Introducer 30mm (1 1/5"), Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

021166-30C10

22G x 103mm (4")

521163-30C25

22G x 103mm (4") with Introducer

221163-30C25

22G x 103mm (4") with Introducer 40mm (1 3/5"), Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

221166-30C10

22G x 120mm (4 3/4") with Introducer

131163-30C10

22G x 120mm (4 3/4") with Introducer 40mm (1 3/5"), Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

131166-30C10

22G x 150mm (6") with Introducer

141163-30C10

22G x 150mm (6") with Introducer 40mm (1 3/5"), Filter needle (blunt) 18G x 50mm (2"), Syringe 3ml Slip, Syringe 5ml Slip

141166-30C10

0.8 x 30mm (1 1/5") for Sprotte 24G, 25G

021163-30L25

0.8 x 40mm (1 3/5") for Sprotte 24G, 25G

021163-30M25

1.00 x 30mm (1 1/5") for Sprotte 22G

001163-30L25

1.00 x 40mm (1 3/5") for Sprotte 22G

001163-30M25
Items
Sprotte Brochure
NRFit Brochure
Sprotte NRFit Instruction for use

Studies:

1 Strupp M., Schueler O., Straube A., Von Stuekrad-Barre S., Brandt T. Atraumatic Sprotte needle reduces the incidence of post-lumbar puncture headaches, Neurol. 2001; 57: 2310–2312
2 Jäger H., Krane M., Schimrigk K. Lumbar puncture – the post-puncture syndrome. Prevention with an „atraumatic“ puncture needle, clinical observations [Article in German] Schweiz Med Wochenschr. 23. Oct. 1993; 123(42):1985–90

NRFit® is a registered trademark of GEDSA and is used with their permission

Not all products are registered and approved for sale in all countries or regions. Indications of use may also vary by country and region. Please contact your country representative for product availability and information. Product images are for reference only.

Filter

Other Interesting Topics

Read More
Regional Anaesthesia Accessories
Read More
NRFit® with PAJUNK®
Read More
About PAJUNK®