The StimuLong Sono II combines the advantages of a stimulating catheter with those of echogenic needles. The StimuLongSono II catheter offers a stimulating tip that provides additional position control and confirmation. The system also allows for post-op stimulation for catheter tip placement confirmation.
The StimuLong Sono II sets are available with echogenic Tuohy and Facet Tip needles and are compatible with all Pajunk nerve stimulators.
Item description | Item no. LUER | Purchase Unit |
---|---|---|
19G x 50mm (2") with Facet Tip / 20G x 50cm catheter with central opening / StimuLong Clamping Adapter (yellow) / Connecting cable / MiniFilter 0,2 µm / FixoLong Mini |
531187-32A | 10 |
19G x 100mm (4") with Facet Tip / 20G x 50cm catheter with central opening / StimuLong Clamping Adapter (yellow) / Connecting cable / MiniFilter 0.2 µm / FixoLong Mini |
521187-32A | 10 |
18G x 50mm (2") with Tuohy Tip / 20G x 50cm catheter with central opening / StimuLong Clamping Adapter (yellow) / Connecting cable / MiniFilter 0.2 µm / FixoLong Mini |
531187-32C | 10 |
18G x 100mm (4") with Tuohy Tip / 20G x 50cm catheter with central opening / StimuLong Clamping Adapter (yellow) / Connecting cable / MiniFilter 0.2 µm / FixoLong Mini |
521187-32C | 10 |
Item description |
19G x 50mm (2") with Facet Tip / 20G x 50cm catheter with central opening / StimuLong Clamping Adapter (yellow) / Connecting cable / MiniFilter 0,2 µm / FixoLong Mini |
|
---|---|---|
Item no. LUER | 531187-32A | 10 |
Item description |
19G x 100mm (4") with Facet Tip / 20G x 50cm catheter with central opening / StimuLong Clamping Adapter (yellow) / Connecting cable / MiniFilter 0.2 µm / FixoLong Mini |
|
Item no. LUER | 521187-32A | 10 |
Item description |
18G x 50mm (2") with Tuohy Tip / 20G x 50cm catheter with central opening / StimuLong Clamping Adapter (yellow) / Connecting cable / MiniFilter 0.2 µm / FixoLong Mini |
|
Item no. LUER | 531187-32C | 10 |
Item description |
18G x 100mm (4") with Tuohy Tip / 20G x 50cm catheter with central opening / StimuLong Clamping Adapter (yellow) / Connecting cable / MiniFilter 0.2 µm / FixoLong Mini |
|
Item no. LUER | 521187-32C | 10 |
Downloads |
---|
PNB Catheters Brochure
|
Studies:
1 Fuzier R. et al. The echogenicity of nerve blockade needles, Anesth. 2015; 70: 462–466
2 Uppal V. et al. Effect of beam steering on the visibility of echogenic and non-echogenic needles: a laboratory study, Can. J. Anesth. 2014 Oct; 61(10): 909–915
3 Hebard S., Hocking G. Echogenic technology can improve needle visibility during ultrasound-guided regional anesthesia, Reg. Anesth. Pain Med. 2011 March–April; 36(2): 185–189
6 Toledano, R. D. et al. Epidural Catheter Design - Histroy, Innovations, and Clinical Implications., Anesthesiology, V 121, No 1, 201